1.2.two Warning Labels Warning Labels Which means You should carefully look at this manual right before use product. The following labels are a. Will not spot the machine on the sloped area. In any other case the accessible once the system system may slide, leading to personalized damage or perhaps the device performs with the mobile malfunction.
Utmost 4 times tasking for a person transmitted beam, leading to superb time resolution and better frame fee.
three. Simply click the upper icon in the monitor (prompts “Update” if you put the cursor on it), the update phase is completed, if fails, make sure you deliver to R&D Centre. Figure six-1 Primary Watch Upkeep Screen 4. Following update is productive, restart the device soon after ability off to produce the information powerful. HDD Partition ... Site 91 structured report linked facts file and DICOM viewing program Report report template obd.bin OBD information file version.txt Model file Comment Comment file AnatomyImage Anatomical photos Measurement Measurement library Doppler application and connected boot configuration key file and plug-ins, remote desktop server Multilanguage string file exe videoplay.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
By continuing your pay a visit to on our Web site, you are consenting to our usage of cookies. Even so, you'll be able to alter your cookie options Anytime. Cookie preference Acknowledge and Move forward
Content material Strategy Test the battery periodically : a) Look at if battery can be billed Ordinarily when power-on: That The existing ability is one hundred% or capability raises following a brief time suggests that the battery is usually billed Usually.
Web page 145 Clear control panel Tools: dry tender cloth, mild soapy h2o Strategy: Use dry delicate fabric to clean the floor in the system. If the procedure is soiled, moisten the tender cloth with gentle soapy h2o and wipe off any stains. Use dry delicate fabric to remove any dampness and permit all difficult surfaces to wholly air-dry. Webpage 146: Clean up The Peripherals
Find out much better diagnostic facts by way of prolonged check out on the anatomical composition on all convex probes.
Analyzing clients in these days’s demanding surroundings calls for modern technological know-how that allows clinicians to help make brief and self-assured diagnoses. The versatility from the DP-fifty expands your medical utility whilst assisting to improve affected individual care.
5.2.three Geometric positioning accuracy Longitudinal geometric positioning accuracy Test Move: Do adjustments as the way in testing the maximum depth. Report the space by 20mm each section around the longitudinal targets line utilizing the measurement caliper; Choose the worth with the greatest error (to 20mm), calculate the precision using the method beneath The measurement caliper really should be positioned at the higher fringe of the goal, Be aware:... Site 79 Transverse geometric positioning precision Examination Phase: Address the scan surface area on the phantom with water or couple gel, Carefully Get in touch with the probe Along with the scan floor Change the depth, generating the transverse targets to get displayed during the impression. Change the focus level for being posited beside the transverse targets (the conventional isn't distinct) Adjust parameters like attain, TGC, making each Dp50rb login transverse targets to generally be Obviously shown. Website page 80 5.five.2.four Blackout Region Test Step: Go over the scan area with the phantom with water or few gel, Carefully Get in touch with the probe While using the scan surface area Regulate the depth at a decrease value, and set the focus at the closest spot to the scan area. Decrease the value of parameters like AP, Obtain until finally the qualifications noise just might be found. Web page eighty one: Computer software Enhance And Maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Take note: Just before uploading the log, ensure that the ultrasound process has actually been linked to network, usually, the program could alert “couldn't hook up with server” The server (smtp.
Functionality Exam five.five.1 Test Procedure Resolution Detection depth Geometric Posture Accuracy Blackout region take a look at Record the Test illustrations or photos five.5.two Check Content The picture utilized Here's just for reference, persist with the image result in the actual Be aware: problem. Demands: Display screen: established the distinction and brightness for the clinical software benefit (or the default position) Procedure surroundings: dim home, simulating the clinical software environment. Website page 76 In issue which the transverse resolution tests targets are horizontally exhibited, document the minimum distance of two targets that may be clearly identified. Repeat the Procedure previously mentioned to the transverse resolution testing targets at other depths. As revealed in determine under. Axial resolution ... Page seventy seven When utilizing the convex probe, continue to keep the transverse resolution tests targets to notice: be exhibited near the midline. When utilizing a linear probe with steer purpose, usually do not activate the steer function when conduct the transverse resolution check. Zoom in the region wherever the targets located if needed. The diameter of the goal place at a specific depth is equivalent towards the transverse resolution with the depth. Web site seventy eight five.
Following replacing the CPU module, key file have to be created Once more based on the new MAC handle and created into HDD with the equipment. Or else, the configuration function in the product is going to be shed. Following eliminating the CPU module, Take out panhead screws with washers (twelve M3X6) preset on the key device box, you might take off the board. Website page 118 Figure 8-29 Disassemble the User interface Assembly (one) Maintain the upper fringe of control panel assembly, and open up the user interface. Figure 8-thirty Disassemble the Control Panel Assembly (2) Following getting rid of a single countersunk head self-tapping screw PT3X10 set around the user interface and acquire out the plug with the keyboard and the leading unit connecting cables, you can eliminate the user interface assembly.
A smart new condition, Improved mobility and hassle-free operation make DP-fifty compatible for all clinical settings.